X ctu download old version






















The 3. Note that the blue RX-to-DataOut connection is reversed at the hex inverter from the other connections. This is because data is flowing in the opposite direction from the XBee back to the computer on the blue wire.

Most often this will be COM1. The default settings are , 8N1 and no flow control. Unless you have changed to another baud rate or configuration on the XBee that you are programming, these default settings should be fine. If this test doesn't succeed, carefully check your wiring and solder connections before proceeding. If you would like to reset everything to the factory defaults, press the Show Defaults button.

Power off modem 2. PKG-U 1. Hold Config Switch 2. Press and release Reset switch 3. Release Config Switch box will close upon succes xTend 1. Press and hold Config Switch for 2 seconds.

Press and release Reset Switch. Dialog Box should close within 1o seconds after switch is released. I have and XBEE how I told you but after I press for 10 seconds the reset switch still I get the message that it can't have communication. Are you using libelium shield with arduino for writing a program using XCTU??

Are you using the latest version of X-CTU? If not, download and install the latest version from the Digi site. There has been one report that after uninstalling an old version it was necessary to delete the program folder and reboot before installing the new version. Without the folder deletion and the reboot the new version was installed, but the old one was still there and was the one that ran.

My transcription of the steps goes as follows: a. Connect the affected module to your interface board and the PC, leaving the interface board disconnected from its power. The video shows a serial board, but it doesn't say you can't use USB. Launch the X-CTU software.

On the Modem Configuration tab, select the correct modem type, function set and firmware version. Click on Show Defaults, and Write. When the Action Required box comes up, hold the reset button in, then apply power to the interface board, then release the reset button.

The Action Required box will then close out. The firmware load will take place, and when completed your module will be functioning properly. Note: this one is a lightly edited quote from Digi Support. Look at the bottom of the RF module and see which model you have.

Then in X-CTU select the correct modem model and click show defaults. You should click on Download New Versions so you have the latest firmware version for your RF modem, and also make sure you have Update Firmware checked. If you can communicate with the module from X-CTU or from a terminal program, try issuing the ATRE command to reset all parameters to their default values. Since the parameter of XBee you connected , has changed by this operation.

It is kind of annoying not necessary to update the firmware all the time , unless you know what it is for. Then change it to "7 - ". On step 7. Make sure you did not check the option "Always update firmware". You will get this information if everything is right.

It tells you it didn't update the firmware and just configure the AT parameters for you. The hardware and official library allows the Baud Rate be set up to bps.

I will have a simple example tutorial for you in this website. If you are using Arduino with a very useful third party library : "NewSoftSerial", the highest Baud Rate is bps.



0コメント

  • 1000 / 1000